Please enable JavaScript to view this site.

winIDEA Help

Version: 9.21.260

Profile OS objects

In this topic:

Configuration steps

Results

 

 

Introduction

This tutorial introduces the Operating System (OS) objects profiling configuration via Automatic Hardware Trigger Configuration.

It shows how to configure your OS, add an RTOS description file which is a necessary step for profiling OS objects.

 

 

Configuration steps

Make sure your winIDEA workspace for tracing is created and debug session established.

 

number1

Go to Debug | Configure Session | Application | Edit and select your operating system.

Profiling-os-objects-orti-xml

 

 

number2

Click the Configure button and specify the RTOS description file.

rtos-orti-file-specify

 

 

number3

Create a New Analyzer Configuration via View | Analyzer | Analyzer Configuration arrow | Create New Configuration.

The configuration should have:

a.Descriptive name

b.Enabled Profiler

c.Enabled Automatic Hardware Trigger

 

Profiling-os-objects-new-config

 

 

Number4

Add a Process via New button.

Profiling-data-tutorial-process

 

When you click on the newly created Process (e.g. App/MS_App), Profiler (and Coverage) pages will appear in the left menu.

 

Number5

Set Recorder options.

Start - Trigger Immediately

(optional) Enabled Upload while sampling to stream trace messages via the DAP interface

 

profiling-data-recorder-winidea

 

Warning_orange

Make sure Manual Hardware Trigger is not checked.

 

 

number6

Enable OS object section and select OS object and values.

profiling-os-objects-runnables

 

 

 

 

Results

profilling-os-objects-results_zoom52

 

 

More resources

Recorder - Configuration details

OS Profiling - Configuration details

 

 

Copyright © 2024 TASKING