Hot Attach

In this topic:

Debug I/O levels

Drive RESET while Detached

Hot Attach procedure

Detach procedure

 

Hot Attach and Detach functionality allows you to attach (and detach) the BlueBox development system to a running target system without affecting its operation and have all debug functions available. As such, it is a very convenient troubleshooting tool when the application malfunctions after a longer time.

 

Debug I/O levels

Warning_or

When using Hot Attach, Debug I/O levels should always be set to fixed voltage based on target I/O voltage level in the Hardware menu / CPU Options / Hardware! (This might not be needed for some newer Active Probe adapters.)

 

HOTAttachDebugIOlevels

 

 

 

Drive RESET while Detached

Warning_or

When using Hot Attach, Drive RESET while Detached should be configured to ''no''  in the Hardware menu / CPU Options / Reset.

 

HotAttachDriveRESET

 

 

Warning_or

10-pin 1.27mm Infineon DAP2 Wide Debug Adapter (IC50163-2) and all Active Probes do not support Hot Attach in a sense of connecting to a live target with the cable. You need to attach the cable to the target before running the application.

 

 

Hot Attach procedure

number1

Target is powered and running.

Your BlueBox is off and physically disconnected to the target.

 

number2

Connect your BlueBox.

Connect your BlueBox GND and the target GND using the grounding wire delivered with the BlueBox.

 

number3

Power on your BlueBox.

Follow the steps of the Power On/Off procedure.

 

Number4

Prepare to Attach.

Select Debug / Prepare to Attach and wait for online-readytoattach status in winIDEA.

 

Number5

Attach to the target.

Now you can safely attach the Debug Adapter or Active Probe to your target. An example of hot-attaching a Debug Adapter to the target.

 

HOT-removed

HOT-attached

 

number6

Hot Attach.

Once connected, select Debug / Attach to establish debug connection with the microcontroller.

 

Warning_or

Using any of the Download or Reset functionalities will in fact reset the microcontroller (whereas in older winIDEA versions Download has been ignored while in the Hot Attach state).

 

Hot Attach on RH850 is not possible with Mictor 38-pin Nexus debug & trace adapter. Use LPD debug connector for Hot Attach.

 

Hot Attach is not supported on MPC51xx devices.

 

 

Detach procedure

info-icon

This procedure can also be executed with or after Debug / Download.

 

number1

Debug session is active.

Your target is powered and running, winIDEA status shows: winIDEA-status-RUN

 

number2

Disconnect debug session via Debug / Detach.

winIDEA status will change to: winIDEA-status-SoC-detached

 

number3

Disconnect Debug Adapter from target.

 

Number4

Disconnect from Debugger via Debug / End Session.

winIDEA status will change to: winIDEA-status-offline

 

Number5

Power off the Debugger.

 