One flat ribbon cable

Debug Adapters, which come with a detached ribbon cable, connect always to DTM #1 connector located on top of the BlueBox.

 

number1

Connect the ribbon cable to the DTM #1 connector.

The cable should be facing away from the BlueBox with the red (edge) wire on the side of the DTM #1 marking. Align the orientation key/notch of the cable connector with the notch on the BlueBox connector marked with #1. Press the cable connector carefully straight down until the latches lock.

 

OneFlatRibbonCable

 

number2

Connect the Debug Adapter to the other side of the ribbon cable.

Align the orientation key/notch on the Debug Adapter connector with the connector on the flat ribbon cable. Press the cable carefully straight down until the latches lock.

 

number3

Connect the Debug Adapter to the Target.

Refer to the chapter Debug Adapter and Target.

 

Number4

Disconnect.

In order to disconnect the flat ribbon cable from the DTM #1 connector, squeeze the two metal latches on the cable connector from the side and pull the cable from the DTM #1 connector.

 

 